- Brand-new appearance, small and lightweight, design as portable;
- 3.5″colorful touchscreen to display various information on one page;
- High-quality PBT enclosure, which makes medical disinfection and cleaning convenient;
- Multi – and Across – combination of syringe pump and infusion pump are enabled by Slide guide and lock catch design, which is safe and practical.
- 7 infusion modes are able to satisfy various clinical needs;
- 10 levels for forgotten operation time are selectable to suit diverse clinical situations;
- Dynamical pressure monitoring with 13 occlusion levels to protect patient’s safety every single second.
- Rate are adjustable during running state;
- Tube fatigue recoup function is designed to recoup insufficient flow volume during long time use.
- High-tech smart alarm system is innovated to Intuitively demonstrate operation instructions;
- Maintenance cycle is settable to prevent users from forgetting regular calibration.
Model | Anim-8 |
Applicable Infusion Set | 1ml/15d, 1ml/19d, 1ml/20d, 1ml/60d, |
Infusion Rate | ml/h mode: 0.1~2000ml/h drop/min mode:1~(400ml/h*d/60) d/min |
Unit Conversion | Conversion between drop/ml and ml/h. |
Bolus Rate & VTBI (Volume to be infused) | Bolus rate: 0.1~1500ml/h VTBI: 0.1~50ml |
FF ate & VTBI | FF rate: 0.1~2000ml/h VTBI: 0.1~9999.99ml |
KVO ate & VTBI | KVO rate: 0.1~5.0ml/h VTBI: 0.1~1ml |
VTBI | 0.1~9999.99ml |
Cumulative Infusion Volume | 0.01~9999.99ml |
Rate Accuracy | Rate ≥ 1ml/h: ≤±3% (after calibration) Rate < 1ml/h: ≤±5% (after calibration) |
Occlusion pressure | 13 occlusion pressure levels |
Air Bubble size | 6 levels (25µl、50µl、100µl、250µl、500µl、800µl) |
Alarms Information | Near infusion end, infusion finished, system standby completed, upstream is blocked, Downstream is blocked, door open, air bubble, forgotten operation, battery low, battery empty, abnormal running state, equipment failure, power failure, Infusion set mismatched, replace the infusion set, drop sensor is pulled out, empty bottle etc. |
Prompts | Parameter overrun, infusion begins, AC power has been pulled out, speed overrun, Set installation error, equipment maintenance |
Power Source | Three options for power supply First: 100~240VAC, 50/60Hz; Second: Inserted Li battery 11.1V, capacity≥2600mAh; After the battery is fully charged, it can be used for infusion pump to work continuously for more than 7h at a rate of 25ml/h and for more than 5h at a rate of 2000ml/h. Third: External DC 15V power supply |
Drug Library | Up to 1000 drugs are provided. |
IP level | IP24 |
Dimensions | 248mm(L)×183mm(W)×83mm(H) |
Screen | 3.5″ Color LCD, touch screen |
WiFi module | Yes |
Communicate with Host | Yes Can be monitored and controlled by Infusion management system FS3 |
communication with HIS | YES |
Compatible dock station | Sunfusion FS3 + CM3 |