Infusion Pump Semi-2

Certified with ISO9001, ISO13485, CE, ISO14001, OHSAS18001, national GB/T29490-2013 and Grade- III of Work Safety Standardization.

  • Brand-new appearance, small and lightweight, design as portable;
  • 3.5″colorful touchscreen to display various information on one page;
  • High-quality PBT enclosure, which makes medical disinfection and cleaning convenient;
  • Multi – and Across – combination of syringe pump and infusion pump are enabled by Slide guide and lock catch design, which is safe and practical.
  • 7 infusion modes are able to satisfy various clinical needs;
  • 10 levels for forgotten operation time are selectable to suit diverse clinical situations;
  • Dynamical pressure monitoring with 13 occlusion levels to protect patient’s safety every single second.
  • Rate are adjustable during running state;
  • Tube fatigue recoup function is designed to recoup insufficient flow volume during long time use.
  • High-tech smart alarm system is innovated to Intuitively demonstrate operation instructions;
  • Maintenance cycle is settable to prevent users from forgetting regular calibration.
Infusion Pump Model Semi-2
Applicable Infusion Set 1ml/15d, 1ml/19d, 1ml/20d, 1ml/60d,
Infusion Rate ml/h mode: 0.1~2000ml/h drop/min mode:1~(400ml/h*d/60) d/min
Unit Conversion Conversion between drop/ml and ml/h.
Bolus Rate & VTBI (Volume to be infused) Bolus rate: 0.1~1500ml/h VTBI: 0.1~50ml
FF ate & VTBI FF rate: 0.1~2000ml/h VTBI: 0.1~9999.99ml
KVO ate & VTBI KVO rate: 0.1~5.0ml/h VTBI: 0.1~1ml
VTBI 0.1~9999.99ml
Cumulative Infusion Volume 0.01~9999.99ml
Rate Accuracy Rate ≥ 1ml/h: ≤±3% (after calibration) Rate < 1ml/h: ≤±5% (after calibration)
Occlusion pressure 13 occlusion pressure levels
Air Bubble size 6 levels (25µl、50µl、100µl、250µl、500µl、800µl)
Alarms Information Near infusion end, infusion finished, system standby completed, upstream is blocked, Downstream is blocked, door open, air bubble, forgotten operation, battery low, battery empty, abnormal running state, equipment failure, power failure, Infusion set mismatched, replace the infusion set, drop sensor is pulled out, empty bottle etc.
Prompts Parameter overrun, infusion begins, AC power has been pulled out, speed overrun, Set installation error, equipment maintenance
Power Source Three options for power supply First: 100~240VAC, 50/60Hz; Second: Inserted Li battery 11.1V, capacity≥2600mAh; After the battery is fully charged, it can be used for infusion pump to work continuously for more than 7h at a rate of 25ml/h and for more than 5h at a rate of 2000ml/h. Third: External DC 15V power supply
Drug Library Up to 1000 drugs are provided.
IP level IP24
Dimensions 248mm(L)×183mm(W)×83mm(H)
Screen 3.5″ Blue LCD, touch screen
WiFi module NO
Communicate with Host NO
communication with HIS NO
Compatible dock station Sunfusion PI3